FIRST FLOOR DECK
DOW SILL SEALER
2X8 PRESSURE TREATED PLATE
DOUBLE 2X10 PERIMETER BAND BOARD/PRESSURE TREATED AT DECK LOCATIONS
2X10 FLOOR JOIST 16" O.C., KILN DRIED SPF
GALVANIZED METAL BRIDGING
¾" TONGUE & GROOVED OSB SUBFLOOR
SUBFLOOR ADHESIVE
EXTERIOR WALLS
2X6 SPF EXTERIOR WALL STUDS @ 16" ON CENTER/ASSEMBLED PANELS
DOUBLE TOP PLATE (TOP PLATE SHIPPED AS LINEAL FOOTAGE)
2X12 SPF HEADERS OVER ALL DOORS AND WINDOWS
7/16" OSB EXTERIOR SHEATHING APPLIED
BARRICADE BUILDING WRAP
R-19 FIBERGLASS INSULATION
½" GYPSUM BOARD (DRYWALL) WITH GLUE AND SCREWS
INTERIOR PARTITION WALLS
2X4 SPF STUD WALLS @ 16" ON CENTER/ASSEMBLED PANELS
2X6 SPF BEARING PARTITION STUD WALLS, 16" ON CENTER
DOUBLE TOP PLATES (TOP PLATE SHIPPED AS LINEAL FOOTAGE)
2X6 SPF HEADERS IN NON BEARING WALLS
½" GYPSUM BOARD (DRYWALL) WITH GLUE AND SCREWS
INSULATED BATHROOM WALLS
SECOND FLOOR FRAMING
2X10/2X8 SPF FLOOR JOIST @ 16" OC CENTER
SOLID GALVANIZED METAL BRIDGING
2X10 SPF PERIMETER BAND BOARD
¾" TONGUE AND GROOVED OSB SUBFLOOR
SUBFLOOR ADHESIVE
½" GYPSUM BOARD (DRYWALL) WITH GLUE AND SCREWS FOR
CEILINGS
ROOF SYSTEM
PREENGINEERED ROOF TRUSS SYSTEM OR
RIDGE - 2X12 SPF AS REQUIRED
RAFTERS - 2X10 SPF AS REQUIRED
TIES - 2X6 SPF AS REQUIRED
RAKE OVERHANGS - FACTORY ASSEMBLED RAKE LADDERS
SUB FASCIA - 2X6 OR 2X8 AS REQUIRED
SHEATHING - 1/16" OSB WITH H-CLIPS
DORMERS - PREBUILT FRAMED COMPONENTS
15 LB. ROOFING FELT
25 YEAR TAMKO ASPHALT SHINGLES
ALUMINUM COIL STOCK FLASHING
SOFFIT - VYNIL VENTED
FASCIA - PRE FORMED VINYL
WINDOWS
CRESTLINE CLAD WITH SCREENS AND GRILLS, EXTENSION JAMBS PRE ASSEMBLED PER DESIGN
HIGH PERFORMANCE INSULATING GLASS
EXTERIOR TRIM - SELECT PINE OR BRICKMOLD
EXTERIOR DOORS
ENTRY DOORS - THERMA - TRU INSULATED FIBERGLASS DOORS (PAINT OR STAIN GRADE) DESIGN PER PLAN, PREHUNG WITH BRICK MOLD OR SELECT PINE WITH SCHLAGE LOCKSETS
PATIO DOORS - CRESTLINE CLAD, WOOD INTERIOR WITH SLIDING SCREEN DOOR, INSULATED GLASS AND BRICKMOLD OR SELECT PINE CASING
INTERIOR MILLWORK
SWING, BIFOLD - COLONIAL 6 PANEL MASONITE OR 6 PANEL SOLID PINE PER SPECIFICATIONS
LOCKSETS BY SCHLAGE, PASSAGE AND PRIVACY
JAMBS - SOLID PINE
STAIRWAYS PRE ASSEMBLED PINE (IF CARPETED) OR OAK PER SPECIFICATIONS
HAND RAILS AND BALUSTERS AND FITTINGS IN OAK
INTERIOR TRIM IN FEATHER EDGE SOLID PINE OR PREFINISHED OAK PER SPECIFICATIONS, CROWN MOLDING IN DINING AND SPECIFIED AREAS (VARIES WITH DESIGN)
INSULATION
R-30 FIBERGLASS INSULATION IN ROOF SYSTEM
R-19, R-13 FIBERGLASS INSULATION IN EXTERIOR STUD WALLS
R-19 FIBERGLASS INSULATION IN FIRST FLOOR SYSTEM OR PER SPECIFICATIONS
MISCELLANEOUS
ALL FASTENERS, HANGERS, NAILS, CONNECTORS
ITEMS SUCH AS FINISH FLOORING, KITCHEN CABINETS, EXTERIOR WALL FINISH ARE PER SPECIFICATIONS AND INDIVIDUAL HOME DESIGN. MANY ALTERNATIVE ITEMS AND MATERIALS ARE AVAILABLE PER SPECIFICATION in Proyecto Mym60 SL.
|
|